HP PRO-T All In One Solar Charge Controller Inverter 1000W-8000W 12V/24V/48V

$704.00$2,300.00

+ Free Shipping

1000W/ 1500W/2000W/3200W/5000W/7000W/8000W DC12V/24V/48V to AC220V/230V/240V | Best All In One MPPT Solar Charge Controller Inverter Combo | High Frequency Design | Solar Charge and AC Charge Combo

  • Type :Off Grid Solar Charge Inverter
  • Brand : BigBear
    Verification: CE / FC / IEC/ ISO / RoH

■ Solar Charge Inverter Feature


 

1. Pure sine wave high frequency solar inverter, high efficiency and low no-load loss;
2. MPPT solar charge controller and inverter combo, It is the most popular integrated design in the market;
3. Battery charge and discharge voltage parameters can be set, Suitable for lead-acid battery, lithium ion battery, gel battery and other battery types;
4. Support solar energy, mains power and generator input, stabilized voltage output;
5. Off grid solar inverter can work without battery optional, saving the cost of solar power system;
6. RS485 communication port/APP optional, convenient to remotely monitor the operation status of the solar charge inverter

■ Solar Charge Inverter Specification


 

Specification
Model: HP pro-T 10212 15224 20224 32224L 32224 50248L 50248 72248 80248
Rated Power 1000W 1500W 2000W 3200W 3200W 5000W 5000W 7200W 8000W
Peak Power(20ms) 3000VA 4.5KVA 6KVA 9.6KVA 9.6KVA 15KVA 15KVA 21.6KVA 24KVA
Battery Voltage 12VDC 24VDC 48VDC
Product Size(L*W*Hmm) 355x272x91.5 400x315x101.5 440x342x101.5 525x355x115
Package Size(L*W*Hmm) 443x350x187 488x393x198 528x420x198 615x435x210
N.W(Kg) 6.5 8.5 10 14
G.W(Kg) 7.5 9.5 11 15.5
Installation Method Wall-Mounted
PV Charging Mode MPPT
MPPT tracking voltage range 15V-80VDC 30V-100VDC 120V-450VDC 60V-140VDC 120V-450VDC
Rated (recommended) operating voltage of PV array 15V-30VDC 30V-60VDC 360VDC 60V-90VDC 360VDC
Max PV Input Voltage Voc
(At the lowest temperature)
120VDC 500VDC 180VDC 500VDC
PV Array Maximum Power 840W 1680W 4000W 3360W 6000W 4500Wx2
MPPT tracking channels (input channels) 1 2
Input DC Input Voltage Range 10.5-15VDC 21VDC-30VDC 42VDC-60VDC
Rated AC input voltage 220VAC  / 230VAC  / 240VAC
AC Input Voltage Range 170VAC~280VAC (UPS mode)/ 120VAC~280VAC(INV mode)
AC Input Frequency Range 45Hz~55Hz(50Hz),55Hz~65Hz(60Hz)
Output Output efficiency(Battery/PV Mode) 94%(Peak value)
Output Voltage(Battery/PV Mode) 220VAC±2%  / 230VAC±2%  / 240VAC±2%
Output Frequency(Battery/PV Mode) 50Hz±0.5 or 60Hz±0.5
Output Wave(Battery/PV Mode) Pure Sine Wave
Efficiency(AC Mode) >99%
Output Voltage(AC Mode) Follow input
Output Frequency(AC Mode) Follow input
Output waveform distortion
Battery/PV Mode)
≤3%(Linear load)
No load loss(Battery Mode) ≤1% rated power
No load loss(AC Mode) ≤0.5% rated power(charger does not work in AC mode)
Battery Battery
Type
VRLA Battery Charge Voltage :13.8V; Float Voltage:13.7V(Single battery voltage)
Customize battery Charging and discharging parameters of different types of batteries can be customized according to user requirements
(charging and discharging parameters of different types of batteries can be set through the operation panel)
Maximum charging current (mains + PV) 120A 100A 110A 120A 100A 120A 100A 150A
Max PV Charging Current 60A 60A 60A 60A 100A 60A 100A 150A
Max AC Charging Current 60A 40A 50A 60A 60A 60A 60A 80A
Charging method Three-stage (constant current, constant voltage, floating charge)
Protection Battery low voltage alarm Battery undervoltage protection value+0.5V(Single battery voltage)
Battery low voltage protection Factory default: 10.5V(Single battery voltage)
Battery over voltage alarm Constant charge voltage+0.8V(Single battery voltage)
Battery over voltage protection Factory default: 17V(Single battery voltage)
Battery over voltage recovery voltage Battery overvoltage protection value-1V(Single battery voltage)
Overload power protection Automatic protection (battery mode), circuit breaker or insurance (AC mode)
Inverter output short circuit protection Automatic protection (battery mode), circuit breaker or insurance (AC mode)
Temperature protection >90°C(Shut down output)
Working Mode Mains priority/PV priority/Battery priority(Can be set)
Transfer Time ≤10ms
Display LCD+LED
Thermal method Cooling fan in intelligent control
Communication(Optional) RS485/APP(WIFI monitoring or GPRS monitoring)
Environment Operating temperature -10℃~40℃
Storage temperature -15℃~60℃
Noise ≤55dB
Elevation 2000m(More than derating)
Humidity 0%~95% (No condensation)
Note: 1. Model of 10212/15224/20224/32224L/50248L only support mains priority mode and battery priority mode, PV priority work mode is not supported.
2. All specifications are subject to charge without prior notice.

 

 

■ Solar Charge Inverter Details

 

■ Solar Charge Inverter Connection

■ Solar Charge Inverter Installation

■ Solar Charge Inverter Package and Delivery

Rated Power

1000w 12VDC, 1500w 24VDC, 2000w 24VDC, 3200w 24VDC, 5000w 48VDC, 7200w 48VDC

Shopping Cart