DPT Stand Alone Solar Inverter for Off Grid Solar PV System 1000W-7000W 12V/24V/48V

+ Free Shipping

1000W 1500W 2000W 3000W 4000W 5000W 6000W 7000W 12V/24V/48V Convert to 110V/120V/220V/230V/240V | Inverter for PV | Stand Alone Inverter Used For Off Grid Solar PV System

  • Type :Stand Alone Solar Inverter
  • Brand :BigBear
  • Verification: CE / FC / IEC/ ISO / RoHS

This product is currently out of stock and unavailable.

■ Stand Alone Solar Inverter Feature


 

1. Stand alone inverter built-in PWM or MPPT solar controller optional, used for off grid solar pv system;
2. Low frequency pure sine wave inverter with toroidal transformer, has stable load carrying capacity;
3. The inverter can be equipped with an external lcd display screen with a length of 3 meters, which is convenient for users to switch the inverter and view the inverter data remotely with one key;
4. Support AC/diesel or gasoline generator/solar input, stable voltage output;
5. AC charge current and solar charge current can be adjusted by the button key;
6. Add fault codes query function, timely obtain inverter fault information and find feasible solutions;
7. RS485 communication port/APP optional.
8. Compatible with lead-acid and lithium batteries.

 

 

■ Stand Alone Solar Inverter Specification


stand alone inverter for pv parameter

Specification
Model: DP-T 10212/24/48 15212/24/48 20212/24/48 30224/48 40224/48 50248 60248 70248
Rated Power 1000W 1500W 2000W 3000W 4000W 5000W 6000W 7000W
Peak Power(20ms) 3000VA 4500VA 6000VA 9000VA 12000VA 15000VA 18000VA 21000VA
Start Motor 1HP 1.5HP 2HP 3HP 3HP 4HP 4HP 5HP
Battery Voltage 12/24/48VDC 24/48VDC 24/48VDC 48VDC
Size(L*W*Hmm) 555*297*184 615*315*209
Packing Size(L*W*Hmm) 620*345*255 680*365*280
N.W.(kg) 12 13 15.5 18 23 24.5 26 27.5
G.W.(kg)(Carton Packing) 14 15 17.5 20 25.5 27 28.5 30
Installation Method Wall-Mounted
Parameter
Input DC Input Voltage Range 10.5-15VDC(Single battery voltage)
AC Input Voltage Range 85VAC~138VAC(110VAC)/ 95VAC~148VAC(120VAC / 170VAC~275VAC(220VAC / 180VAC~285VAC(230VAC)
/ 190VAC~295VAC(240VAC)
AC Input Frequency Range 45Hz~55Hz(50Hz) / 55Hz~65Hz(60Hz)
Max AC charging current 0~30A(Depending on the model)
AC charging method Three-stage (constant current, constant voltage, floating charge)
Output Efficiency(Battery Mode) ≥85%
Output Voltage(Battery Mode) 110VAC±2% / 120VAC±2% / 220VAC±2% / 230VAC±2% / 240VAC±2%
Output Frequency(Battery Mode) 50/60Hz±1%
Output Wave(Battery Mode) Pure Sine Wave
Efficiency(AC Mode) >99%
Output Voltage(AC Mode) 110VAC±10% / 120VAC±10% / 220VAC±10% / 230VAC±10% / 240VAC±10%
Output Frequency(AC Mode) Follow input
Output waveform distortion
(Battery Mode)
≤3%(Linear load)
No load loss(Battery Mode) ≤0.8% rated power
No load loss(AC Mode)  ≤2% rated power( charger does not work in AC mode)
No load loss(Energy saving Mode) ≤10W
Battery Type VRLA Battery Charge Voltage :14V; Float Voltage:13.8V( 12V system; 24V system x2 ; 48V system x4)
Customize battery Charging and discharging parameters of different types of batteries can be customized according to user requirements
(charging and discharging parameters of different types of batteries can be set through the operation panel)
Protection Battery undervoltage alarm Factory default: 11V(12V system; 24V system x2; 48V system x4)
Battery undervoltage protection Factory default: 10.5V(12V system; 24V system x2; 48V system x4)
Battery overvoltage alarm Factory default: 15V(12V system; 24V system x2; 48V system x4)
Battery overvoltage protection Factory default:  17V(12V system; 24V system x2; 48V system x4)
Battery overvoltage recovery voltage Factory default:  14.5V(12V system; 24V system x2; 48V system x4)
Overload power protection Automatic protection (battery mode), circuit breaker or insurance (AC mode)
Inverter output short circuit protection Automatic protection (battery mode), circuit breaker or insurance (AC mode)
Temperature protection >90°C(Shut down output)
Alarm A Normal working condition, buzzer has no alarm sound
B Buzzer sounds 4 times per second when battery failure, voltage abnormality, overload protection
C When the machine is turned on for the first time, the buzzer will prompt 5 when the machine is normal
Inside Solar controller
(Optional)
Charging Mode PWM or MPPT
Charging current 10A~60A(PWM or MPPT) 10A~60A(PWM )  / 10A~100A(MPPT)
PV Input Voltage Range PWM: 15V-44V(12V system); 30V-44V(24V system); 60V-88V(48V system)
MPPT: 15V-120V(12V system); 30V-120V(24V system); 60V-120V(48V system)
Max PV Input Voltage(Voc)
(At the lowest temperature)
PWM: 50V(12V/24V system); 100V(48V system) / MPPT: 150V(12V/24V/48V system)
PV Array Maximum Power 12V system: 140W(10A)/280W(20A)/420W(30A)/560W(40A)/700W(50A)/840W(60A)/1120W(80A)/1400W(100A);
24V system: 280W(10A)/560W(20A)/840W(30A)/1120W(40A)/1400W(50A)/1680W(60A)/2240W(80A)/2800W(100A);
48V system: 560W(10A)/1120W(20A)/1680W(30A)/2240W(40A)/2800W(50A)/3360W(60A)/4480W(80A)/5600W(100A)
Standby loss ≤3W
Maximum conversion efficiency >95%
Working Mode Battery First/AC First/Saving Energy Mode
Transfer Time ≤4ms
Display LCD(External LCD Display(Optional))
Thermal method Cooling fan in intelligent control
Communication(Optional) RS485/APP(WIFI monitoring or GPRS monitoring)
Environment Operating temperature -10℃~40℃
Storage temperature -15℃~60℃
Noise ≤55dB
Elevation 2000m(More than derating)
Humidity 0%~95% ,No condensation

 

 

■ Stand Alone Solar Inverter Details

■ Stand Alone Solar Inverter Connection

BigBear LLC stand alone inverter has two usage methods:

 

1. Solar PV System: The electricity generated by solar energy is DC, and will flow into the battery to store energy, then the inverter converts the DC in the battery into the AC of home appliances. When battery power is lacking, it will automatic transfer to grid power for powering continuously.

 

2. UPS Backup System: When AC grid power is available, inverter charges battery, at the same time, AC grid power bypass through inverter to home appliances, such as fan, light, refrigerator, television, computer, air conditioner. When AC grid power is off, inverter will automatic transfer switch to battery power and convert DC to AC power.

 

 

■ Stand Alone Solar Inverter Installation

■ Stand Alone Solar Inverter Package and Delivery

 

Shopping Cart