■ Full Sine Wave Inverter Feature
1, Low frequency inverter with toroidal transformer, full sine wave inverter;
2, AC charger/diesel or gasoline generator charger/solar charger in one;
3, Integrated LCD display. One-button start with an external display screen( optional);
4, Inverter applicable to various battery types: lithium battery, lead acid battery, gel battery, etc;
5, With voltage stabilizing function (AVR output);
6, Telecommunication: RS485/APP(WIFI or GPRS);
7, Necessary for power failure, can be used as UPS power supply.
■ Full Sine Wave Inverter Specification
pure sine wave inverter 220v 240v 230v 110v specification
Specification | |||||||||
Model: DP | 10212/24/48 | 15212/24/48 | 20212/24/48 | 30224/48 | 40224/48 | 50248 | 60248 | 70248 | |
Rated Power | 1000W | 1500W | 2000W | 3000W | 4000W | 5000W | 6000W | 7000W | |
Peak Power(20ms) | 3000VA | 4500VA | 6000VA | 9000VA | 12000VA | 15000VA | 18000VA | 21000VA | |
Start Motor | 1HP | 1.5HP | 2HP | 3HP | 3HP | 4HP | 4HP | 5HP | |
Battery Voltage | 12/24/48VDC | 24/48VDC | 24/48VDC | 48VDC | |||||
Size(L*W*Hmm) | 555*297*184 | 615*315*209 | |||||||
Packing Size(L*W*Hmm) | 620*345*255 | 680*365*280 | |||||||
N.W.(kg) | 12 | 13 | 15.5 | 18 | 23 | 24.5 | 26 | 27.5 | |
G.W.(kg)(Carton Packing) | 14 | 15 | 17.5 | 20 | 25.5 | 27 | 28.5 | 30 | |
Installation Method | Wall-Mounted | ||||||||
Parameter | |||||||||
Input | DC Input Voltage Range | 10.5-15VDC(Single battery voltage) | |||||||
AC Input Voltage Range | 85VAC~138VAC(110VAC)/ 95VAC~148VAC(120VAC / 170VAC~275VAC(220VAC / 180VAC~285VAC(230VAC) / 190VAC~295VAC(240VAC) |
||||||||
AC Input Frequency Range | 45Hz~55Hz(50Hz) / 55Hz~65Hz(60Hz) | ||||||||
Max AC charging current | 0~30A(Depending on the model) | ||||||||
AC charging method | Three-stage (constant current, constant voltage, floating charge) | ||||||||
Output | Efficiency(Battery Mode) | ≥85% | |||||||
Output Voltage(Battery Mode) | 110VAC±2% / 120VAC±2% / 220VAC±2% / 230VAC±2% / 240VAC±2% | ||||||||
Output Frequency(Battery Mode) | 50/60Hz±1% | ||||||||
Output Wave(Battery Mode) | Pure Sine Wave | ||||||||
Efficiency(AC Mode) | >99% | ||||||||
Output Voltage(AC Mode) | 110VAC±10% / 120VAC±10% / 220VAC±10% / 230VAC±10% / 240VAC±10% | ||||||||
Output Frequency(AC Mode) | Follow input | ||||||||
Output waveform distortion (Battery Mode) |
≤3%(Linear load) | ||||||||
No load loss(Battery Mode) | ≤0.8% rated power | ||||||||
No load loss(AC Mode) | ≤2% rated power( charger does not work in AC mode) | ||||||||
No load loss(Energy saving Mode) | ≤10W | ||||||||
Battery Type | VRLA Battery | Charge Voltage :14V; Float Voltage:13.8V( 12V system; 24V system x2 ; 48V system x4) | |||||||
Customize battery | Charging and discharging parameters of different types of batteries can be customized according to user requirements (charging and discharging parameters of different types of batteries can be set through the operation panel) |
||||||||
Protection | Battery undervoltage alarm | Factory default: 11V(12V system; 24V system x2; 48V system x4) | |||||||
Battery undervoltage protection | Factory default: 10.5V(12V system; 24V system x2; 48V system x4) | ||||||||
Battery overvoltage alarm | Factory default: 15V(12V system; 24V system x2; 48V system x4) | ||||||||
Battery overvoltage protection | Factory default: 17V(12V system; 24V system x2; 48V system x4) | ||||||||
Battery overvoltage recovery voltage | Factory default: 14.5V(12V system; 24V system x2; 48V system x4) | ||||||||
Overload power protection | Automatic protection (battery mode), circuit breaker or insurance (AC mode) | ||||||||
Inverter output short circuit protection | Automatic protection (battery mode), circuit breaker or insurance (AC mode) | ||||||||
Temperature protection | >90°C(Shut down output) | ||||||||
Alarm | A | Normal working condition, buzzer has no alarm sound | |||||||
B | Buzzer sounds 4 times per second when battery failure, voltage abnormality, overload protection | ||||||||
C | When the machine is turned on for the first time, the buzzer will prompt 5 when the machine is normal | ||||||||
Working Mode | Battery First/AC First/Saving Energy Mode | ||||||||
Transfer Time | ≤4ms | ||||||||
Display | LCD(External LCD Display(Optional)) | ||||||||
Thermal method | Cooling fan in intelligent control | ||||||||
Communication(Optional) | RS485/APP(WIFI monitoring or GPRS monitoring) | ||||||||
Environment | Operating temperature | -10℃~40℃ | |||||||
Storage temperature | -15℃~60℃ | ||||||||
Noise | ≤55dB | ||||||||
Elevation | 2000m(More than derating) | ||||||||
Humidity | 0%~95% ,No condensation |
■ Full Sine Wave Inverter Details
pure sine wave inverter 220v 240v 230v 110v details
■ Full Sine Wave Inverter Wiring Diagram
pure sine wave inverter 220v 240v 230v 110v wiring diagram
BigBearfull sine wave inverter usually has the following three working mode:
1. UPS Backup System:
When AC grid power is available, inverter charges battery, at the same time, AC grid power bypass through inverter to househould appliances, such as light, rice cooker, refrigerator, air conditioner, TV, computer. When AC grid power is cut off, inverter will automatic transfer switch to battery power and convert DC to AC power.
2. Wind or Solar Power System:
The electricity generated by solar or wind energy is DC (direct current), inverter will convert DC to AC power. When battery power is lacking, it will automatic transfer to AC grid power for powering continuously.
3. Energy Saving System:
Under battery mode, when the load is 5% lower than the rated load, the inverter will intermittently interrupt the inverter output to save electric energy. When the load is greater than 5% of the rated load, the inverter will always be in your convenient state.
■ Full Sine Wave Inverter Application
■ Full Sine Wave Inverter Package and Delivery