■ Reliable Pure Sine Wave Inverter Feature

 


 

1 Inverter pure sine wave output;

2 High efficiency toroidal transformer lower loss ;

3 Intelligent LCD integration display;

4 AC charge current 0-20A adjustable; battery capacity configuration more flexible;

5 Three types working modes adjustable:AC first, DC first, energy-saving mode;

6 Frequency adaptive function, adapt to different grid environments;

7 Added fault code query function,facilitate user to monitor the operation state in real time;

8 Inverter supports diesel or gasoline generator input, adapt any tough electricity situation;

9 RS485 communication port/APP optional.

 

 

■ Reliable Pure Sine Wave Inverter Specification

 


 

 

 

 

Specification
Model WD 80248/96/192
(802)
10348/96/192
(103)
12396/192
(123)
Rated Power 8000W 10000W 12000W
Peak Power(20ms) 24000VA 30000VA 36000VA
Start Motor 5HP 7HP 7HP
Battery Voltage 48/96/192VDC 48/96V/192VDC 96/192VDC
Size(L*W*Hmm) 540x350x695
Packing Size(L*W*Hmm) 600*410*810
N.W.(kg) 66 70 77
G.W.(kg) 77 81 88
Installation Method Tower
Input DC Input Voltage Range 10.5-15VDC(Single battery voltage)
AC Input Voltage Range 92VAC~128VAC(110VAC) / 102VAC~138VAC(120VAC) / 185VAC~255VAC(220VAC) /
195VAC~265VAC(230VAC) / 205VAC~275VAC( 240VAC) (8KW~40KW)
AC Input Frequency Range 45Hz~55Hz(50Hz)/ 55Hz~65Hz(60Hz)
Max AC charging current 0A~40A(Depending on the model,The maximum charging power is 1/4 of the rated power)
AC charging method Three-stage (constant current, constant voltage, floating charge)
Output Efficiency(Battery Mode) ≥85%
Output Voltage(Battery Mode) 110VAC±2% / 120VAC±2% / 220VAC±2% / 230VAC±2% / 240VAC±2%
Output Frequency(Battery Mode) 50Hz±0.5 or 60Hz±0.5
Output Wave(Battery Mode) Pure Sine Wave
Efficiency(AC Mode) >99%
Output Voltage(AC Mode) Follow input
Output Frequency(AC Mode) Tracking Automatically
Output waveform distortion
(Battery Mode)
≤3%(Linear load)
No load loss(Battery Mode) ≤1% rated power
No load loss(AC Mode) ≤2% rated power( charger does not work in AC mode)
No load loss
(Energy saving Mode)
≤10W
Battery Type
(selectable)
VRLA Battery Charge Voltage :14.2V; Float Voltage:13.8V(Single battery voltage)
Customize battery Charging and discharging parameters of different types of batteries can be customized according to user requirements
(charging and discharging parameters of different types of batteries can be set through the operation panel)
Protection Battery undervoltage alarm Factory default: 11V(Single battery voltage)
Battery undervoltage protection Factory default: 10.5V(Single battery voltage)
Battery overvoltage alarm Factory default: 15V(Single battery voltage)
Battery overvoltage protection Factory default: 17V(Single battery voltage)
Battery overvoltage recovery voltage Factory default: 14.5V(Single battery voltage)
Overload power protection Automatic protection (battery mode), circuit breaker or insurance (AC mode)
Inverter output short circuit protection Automatic protection (battery mode), circuit breaker or insurance (AC mode)
Temperature protection >90°C(Shut down output)
Alarm A Normal working condition, buzzer has no alarm sound
B Buzzer sounds 4 times per second when battery failure, voltage abnormality, overload protection
C When the machine is turned on for the first time, the buzzer will prompt 5 when the machine is normal
Working Mode Battery First/AC First/Saving Energy Mode
Transfer Time ≤4ms
Display LCD
Thermal method Cooling fan in intelligent control
Communication(Optional) RS485/APP(WIFI monitoring or GPRS monitoring)
Environment Operating temperature -10℃~40℃
Storage temperature -15℃~60℃
Noise ≤55dB
Elevation 2000m(More than derating)
Humidity 0%~95% ,No condensation
Note: All specifications are subject to charge without prior notice

 

 

■ Reliable Pure Sine Wave Inverter Details

 

■ Reliable Pure Sine Wave Inverter Wiring Diagram

 

We offer 3 optional working modes for inverter (transfer time≤4ms):

 

01 Grid priority mode: When the grid and battery are connected to the inverter, grid will supply power to the loads directly after voltage being stabilized and charge batteries via inverter. When the grid is cut off, the battery will automatically continue to supply power via inverter.

 

02 Energy saving mode: If the power of the connected AC loads is lower than 5% of the inverter’s rated power, there will be no output from the inverter. Only the chip of inverter is working. The power consumption of the inverter is only 1~6W. The LCD shows the output voltage 0. If the power of the connected loads is over 5%, within 5S the inverter will automatically convert DC to AC to supply power for the loads . The LCD shows the output voltage.

 

03 Battery priority mode: When the grid and battery are connected to the inverter, battery will supply power to the loads first. When battery capacity is not enough, the grid will continue to supply power automatically.

 

 

■ Reliable Pure Sine Wave Inverter Application

 

■ Inverter Package and Delivery

Rated Power

8kW DC48/96/192V, 10kW DC48/96/192V, 12kW DC96/192V