4000W/5000W/6000W/7000W, DC24V/48V to AC110V/120V/220V/230V/240V | Inverter with 10A-100A PWM/MPPT Solar Controller | Power Inverter Charger for Camping, Camper, Campervan

  • Type :DC to AC Off-Grid Inverter
  • Brand : BigBear
    Verification: CE / FC / IEC/ ISO / RoHS

 Camper Power Inverter Charger Feature

 


campervan camping inverter – camper power inverter charger

1 Powe inverter with built-in PWM or MPPT controller optional;

2 Low frequency toroidal transformer increase efficiency,Pure sine wave output;
3 Dedicated DCP chip design; stable and high-speed operation;
4 LCD display, One-button start with an external display screen(optional), easy to monitor the operation condition in real time;
5 AC charge current 0-30A adjustable; battery capacity configuration more flexible;
6 Three types working modes adjustable:AC first, DC first, energy-saving mode;
7 AVR output, all-around automatic protection function;
8 Added fault codes query function,facilitate user to monitor the operation state in real time;
9 Supports diesel or gasoline generator, adapt any tough electricity situation;
0 RS485 communication port/APP (WIFI or GPRS) optional.

■ Camper Power Inverter Charger Specification

 


 

Specification
Model: DP-T 40224/48 50248 60248 70248
Rated Power 4000W 5000W 6000W 7000W
Peak Power(20ms) 12000VA 15000VA 18000VA 21000VA
Start Motor 3HP 4HP 4HP 5HP
Battery Voltage 24/48VDC 48VDC
Size(L*W*Hmm) 615*315*209
Packing Size(L*W*Hmm) 680*365*280
N.W.(kg) 23 24.5 26 27.5
G.W.(kg)(Carton Packing) 25.5 27 28.5 30
Installation Method Wall-Mounted
Parameter
Input DC Input Voltage Range 10.5-15VDC(Single battery voltage)
AC Input Voltage Range 85VAC~138VAC(110VAC) / 95VAC~148VAC(120VAC) / 170VAC~275VAC(220VAC) / 180VAC~285VAC(230VAC) / 190VAC~295VAC(240VAC)
AC Input Frequency Range 45Hz~55Hz(50Hz) / 55Hz~65Hz(60Hz)
Max AC charging current 0~30A(Depending on the model)
AC charging method Three-stage (constant current, constant voltage, floating charge)
Output Efficiency(Battery Mode) ≥85%
Output Voltage(Battery Mode) 110VAC±2% / 120VAC±2% / 220VAC±2% / 230VAC±2% / 240VAC±2%
Output Frequency(Battery Mode) 50/60Hz±1%
Output Wave(Battery Mode) Pure Sine Wave
Efficiency(AC Mode) >99%
Output Voltage(AC Mode) 110VAC±10% / 120VAC±10% / 220VAC±10% / 230VAC±10% / 240VAC±10%
Output Frequency(AC Mode) Tracking Automatically
Output waveform distortion
(Battery Mode)
≤3%(Linear load)
No load loss(Battery Mode) ≤0.8% rated power
No load loss(AC Mode) ≤2% rated power( charger does not work in AC mode)
No load loss(Energy saving Mode) ≤10W
Battery Type VRLA Battery Charge Voltage :14V; Float Voltage:13.8V( 12V system; 24V system x2 ; 48V system x4)
Customize battery
Charging and discharging parameters of different types of batteries can be customized according to user requirements
(charging and discharging parameters of different types of batteries can be set through the operation panel)
Protection Battery undervoltage alarm Factory default: 11V(12V system; 24V system x2; 48V system x4)
Battery undervoltage protection Factory default: 10.5V(12V system; 24V system x2; 48V system x4)
Battery overvoltage alarm Factory default: 15V(12V system; 24V system x2; 48V system x4)
Battery overvoltage protection Factory default: 17V(12V system; 24V system x2; 48V system x4)
Battery overvoltage recovery voltage Factory default: 14.5V(12V system; 24V system x2; 48V system x4)
Overload power protection Automatic protection (battery mode), circuit breaker or insurance (AC mode)
Inverter output short circuit protection Automatic protection (battery mode), circuit breaker or insurance (AC mode)
Temperature protection >90°C(Shut down output)
Alarm A Normal working condition, buzzer has no alarm sound
B Buzzer sounds 4 times per second when battery failure, voltage abnormality, overload protection
C When the machine is turned on for the first time, the buzzer will prompt 5 when the machine is normal
Inside Solar controller
(Optional)
Charging Mode PWM or MPPT
Charging current 10A~60A(PWM ) / 10A~100A(MPPT)
PV Input Voltage Range PWM: 30V-44V(24V system); 60V-88V(48V system) / MPPT: 30V-120V(24V system); 60V-120V(48V system)
Max PV Input Voltage(Voc)
(At the lowest temperature)
PWM: 50V(24V system); 100V(48V system) / MPPT: 150V(24V/48V system)
PV Array Maximum Power
24V system: 280W(10A)/560W(20A)/840W(30A)/1120W(40A)/1400W(50A)/1680W(60A)/2240W(80A)/2800W(100A);
48V system: 560W(10A)/1120W(20A)/1680W(30A)/2240W(40A)/2800W(50A)/3360W(60A)/4480W(80A)/5600W(100A)
Standby loss ≤3W
Maximum conversion efficiency >95%
Working Mode Battery First/AC First/Saving Energy Mode
Transfer Time ≤4ms
Display LCD(External LCD Display(Optional))
Thermal method Cooling fan in intelligent control
Communication(Optional) RS485/APP(WIFI monitoring or GPRS monitoring)
Environment Operating temperature -10℃~40℃
Storage temperature -15℃~60℃
Noise ≤55dB
Elevation 2000m(More than derating)
Humidity 0%~95% ,No condensation
Note: All specifications are subject to charge without prior notice

■ Camper Power Inverter Charger Details

 

 

■ Camper Power Inverter Charger Wiring Diagram

BigBear LLC power inverter charger usually has two application methods:

1. Home or Camping or Camper Backup System:
When AC grid power is available, inverter charges battery, at the same time, AC grid power bypass and stable voltage through inverter to home/campervan appliances, such as light, fan, refrigerator, kettle, television, air-conditioner. When AC grid power is off, inverter will automatic transfer switch to battery power and convert DC to AC power.

2. Wind or Solar Energy system:
The electricity generated by solar or wind energy is DC (direct current), then inverter will convert DC to AC power. When battery power is lacking, it will automatic transfer to grid power for powering continuously.

 

■ Camper Power Inverter Charger Application

 

■ Inverter Package and Delivery

Shopping Cart