ES Hybrid Solar Grid Tie Inverter 15KW-25KW 192V/240V

$9,372.00$13,249.00

+ Free Shipping

15KW/20KW/25KW, DC192V/240V to AC220V/230V | Inverter with Dual MPPT Charge Controller | Hybrid Solar On/Off Grid Tie Inverter

  • Type :DC to AC On/Off-Grid Inverter
  • Brand : BigBear
    Verification: CE / FC / IEC/ ISO / RoHS 

■ Why Use Hybrid Solar Grid Tie Inverter


 

1: Peak clipping and valley filling to help you earning revenue

During the valley period (when the electricity price is low), the power grid charge the battery through the inverter. During the peak period (when the electricity price is high), the inverter send full power to the grid. Under the condition of satisfying the load demand, the battery power is also fed to the power grid, to achieve the purpose of selling electricity to grid. By using the hybrid solar grid tie inverter, it is not only reduce the pressure of electricity, but also obtain the economic benefits of peak valley difference in electricity charges.

Peak and valley time periods can be set up by users.

2: Off-grid power generation, which can be used as a backup power source when the power grid is cut off

In the event of a power grid failure, the grid-tied mode of the inverter stops working, and switch to off-grid mode automatically, solar power continues to be generated to provide uninterrupted power to the loads, and the remaining photovoltaic energy is stored in batteries

3: Photovoltaic energy is fully utilized

The system uses PV energy as priority at any working modes, when the energy of PV is not enough, it can be supplemented by power grid or batteries. When the PV energy is surplus, the battery is stored or send to the grid, to achieve the purpose of self-use and extra power send to the grid, realize the full use of PV power generation

4: Both PV/AC can charge the batteries

This hybrid solar grid tie inverter is compatible with lead-acid battery, lithium ion and other battery types. Both PV/AC can charge the batteries with 3 section/2 section charging mode, it can prolong the battery service life.

5: Auto power on, convenient for unattended operation

In the state of power grid supply and photovoltaic power supply, the hybrid solar grid tie inverter automatically starts up to facilitate the power management in the case of unattended.

6: High inverter efficiency, Innovative technology

There is no loss when grid supply power to the loads through inverter. When photovoltaic and battery supply power to loads, the inverter loss is less than 10%, leading among peers.

 

 

 

 

■ Hybrid Solar Grid Tie Inverter Feature


 

1 Integrated intelligent energy management system, a variety of modes can be set;

2 Hybrid solar grid tie inverter cut peaks and fill valleys to reduce grid pressure and maximize profits;

3 Dual MPPT input, precise algorithm, efficient use of PV energy;

4 Supports multiple parallel operations for user expansion;

5 3-stage/2-stage charging technology to protect battery life;

6 Two-way energy storage design, PV, mains can charge the battery;

7 Support multiple remote monitoring of communication software (RS232RS485Mobile APPSNMPGSM).

 

 

■ Hybrid Solar Grid Tie Inverter Specification


 

 

Parameters
Model: ES 153192 203192 253240
PV Input
Max input voltage(Voc)
(At the lowest temperature)
450V 500V
MPPT tracking range 240V-360V 300V-400V
Recommended operating voltage range 240V-320V 300V-380V
MPPT route number 2
Max input power 8.8KW/8.8KW 11.2KW/11.2KW 14KW/14KW
Battery Type of battery Lead-acid battery / Lithium-ion battery
Rated voltage 192V 192V 240V
Max charging current
(Can be set,Recommended 0.1C)
80A(PV)/ 40A(Mains) 110A(PV)/ 60A(Mains) 110A(PV)/ 60A(Mains)
Float voltage(Can be set) 220.8V 276V
Charge voltage(Can be set) 227.2V 284V
Charging method 3-stage/2-stage
AC Input Rated voltage 220V/230V
Input voltage range 187V~264V
Rated input frequency 45Hz~55Hz(50Hz) / 55Hz~65Hz(60Hz)
Islanding Protection ≤2S
Reconnection time 30S
AC output
(off grid mode)
Rated output power 15KW 20KW 25KW
Rated output voltage 220V/230V
Output voltage accuracy ±2%
Rated output frequency 50Hz/60Hz
Output frequency accuracy ±1%
AC output
(on grid mode)
Rated output power 15KW 20KW 25KW
Rated output current 68.2A 90.1A 113.6A
Output voltage 187V~264V
Output frequency 47~52Hz/57~62Hz
Power Factor >0.99(Rated power)
Protection Output short circuit Yes
Over load Yes
Over-voltage/under-voltage Yes
Over-frequency/under-frequency Yes
Over temperature Yes
Island protection Yes
Regular Parameter Topology Transformer isolation
Display LCD+LED
Communication(Optional) RS485/APP(WIFI monitoring or GPRS monitoring)
Operating temperature -10℃~60℃(Derating above 45°C)
Storage temperature -20℃~60℃
Noise ≤60dB
Relative humidity 0%~95%(No condensation)
Highest altitude 2000m(More than derating)
Machine dimension(L*W*Hmm) 620*380*825
Package dimension(L*W*Hmm) 680*440*950
N.W(kg) 128 134 140
G.W(kg) 140 146 152
Installation Method Tower
Note: All specifications are subject to charge without prior notice

 

■ Hybrid Solar Grid Tie Inverter Details

■ Hybrid Solar Grid Tie Inverter Wiring Diagram

There are three working modes for the hybrid solar grid tie inverter:

Main working modes shown as below according to different status and condition. AC/DC switching key (the key is at the back of the hybrid solar grid tie inverter). If you select AC, the priority mode will be the power grid supply ; If you select DC, the priority mode will be the battery supply.

1) AC mode

1 When the power grid is normal and the current solar power generation is bigger than the load power, solar power will feed the load completely and the surplus solar power will feed the battery and transmit to the grid.

2 When power grid is normal and the solar power is smaller than the load power, the insufficient part is supplemented by the grid; The solar and the grid feed the load together.

3 When power grid is abnormal, the inverter changes to independent invert mode. When the solar power is bigger than the load power, the solar power will feed the load completely, and the surplus part will charge the battery. When the solar power is smaller than the load power, the insufficient part is supplemented by the battery; the batteries and the solar feed the load together.

4 When solar has no generating power, the grid will charge and store energy to the battery through the inverter.

5 When power grid is abnormal and there is no solar, batteries will feed the load.

 

Advantages under AC mode:

 

1. The hybrid solar grid tie system gives priority to the use of solar power , and when the solar power is not enough for the local load, it will be supplemented by the power grid, which can make full use of the solar power.

2. The battery will only discharge when the solar power is insufficient and the grid fails. Under normal circumstances, the battery is always in a fully charged state, so it will greatly extend the life of the battery.

2) Battery mode

1 When the power grid is normal and the current solar power generation is bigger than the load power, solar power will feed the load completely and the surplus solar power will feed the battery and transmit to the grid.

2 When the solar power is smaller than the load power, the insufficient part is supplemented by the battery. The solar and the battery will feed the load together.

3 When solar power runs out or very little and the battery is placed to below 192V or 240V (Depends on different solar system voltage), the discharge power of the battery will be linearly reduced. The insufficient part will be supplemented by power grid. And when it reaches the low-voltage protection of the battery, the load will be completely feed by the grid.

4 When power grid is abnormal, the inverter will work in the independent invert mode. The solar power will feed the load. And if the solar power is insufficient, it is supplemented by the battery.

Note: under the BATT mode, if there is no solar, power grid won’t charge the battery.

 

Advantages under battery mode:

 

1. The hybrid solar grid tie system gives priority to the use of solar power, and the power gird is only used as the last supplementary power supply when the solar and battery are insufficient, which greatly reduces the user\’s electricity cost.

2. There is no frequent switching between the battery and the power grid, the battery has a small number of charging and discharging, and the life is relatively long.

3. Solar/battery and grid complement each other perfectly, and the load power supply is stable.

3) Peak-cutting and Valley-filling of power-using Mode (This mode needs to work in inverter battery priority mode)

This mode is suitable for the areas which have peak and valley electricity price. According to the electricity price in different periods, the corresponding time can be set to charge and discharge from the grid.

1 When the electricity price is low, power grid charges the batteries;

2 When the electricity price is high, the batteries feed the loads.

 

 

■ Hybrid Solar Grid Tie Inverter Application

 

■ Inverter Package and Delivery

 

Rated Power

15KW/DC192V, 20KW/DC192V, 25KW/DC240V

Shopping Cart