3 phase off grid hybrid solar inverter can be used in single-phase and three-phase ac load with total power not exceeding 10kva/10kw/15kva/20kva/25kva/30kva, 48v/96v/192vdc to 380vac.

  • Type :DC to AC Off-Grid Inverter
  • Brand :BigBear
  • Verification: CE / FC / IEC/ ISO / RoHS

■ 3 Phase Off Grid Hybrid Solar Inverter Feature

 


1 Pure sine wave output.
2 Low DC voltage, saving system cost.
3 3 phase solar inverter with built-in PWM or MPPT charge controller.
4 AC charge current 0-45A adjustable.
5 Wide LCD screen, clearly and precisely shows icon data.
6 100% imbalance loading design, 3 times peak power.
7 Setting different working modes based on variable usage requirements.
8 DC first/AC first optional.
9 Various communication ports and remote controls (RS232/RS485/APP/SNMP/GSM optional).

 

■ 3 Phase Off Grid Hybrid Solar Inverter Specification

 


 

Specification
Model: HDSX 10KVA 12.5KVA 15KVA 20KVA 25KVA 30KVA
Rated Power 8KW 10KW 12KW 16KW 20KW 24KW
Peak Power(20ms) 24KVA 30KVA 36KVA 48KVA 60KVA 72KVA
Start Motor 5HP 6HP 7HP 10HP 10HP 15HP
Battery Voltage 48/96/192VDC 96/192VDC
Size(L*W*Hmm) 725*365*1010
Packing Size(L*W*Hmm) 785*425*1135
N.W.(kg) 112 122 134 160 176 189
G.W.(kg)(Wooden Packing) 136 146 158 184 200 213
Installation Method Tower
Parameter
Input DC Input Voltage Range 10.5VDC-15VDC(Single battery voltage)
AC Input Voltage Range 380Vac/400Vac±10%(customized 190Vac/200Vac)
AC Input Frequency Range 45Hz-55Hz(50Hz)/ 55Hz-65Hz(60Hz)
Max AC charging current 0-45A(Depending on the model)
AC charging method Three-stage (constant current, constant voltage, floating charge)
Phase 3/N/PE
Output Efficiency(Battery Mode) ≥85%
Output Voltage(Battery Mode) 380Vac/400Vac±10%(customized 190Vac/200Vac)
Output Frequency(Battery Mode) 50/60Hz ±1%
Output Wave(Battery Mode) Pure Sine Wave
Output waveform distortion Linear load≤3%
Efficiency(AC Mode) >99%
Output Voltage(AC Mode) Conforming to AC input
Output Frequency(AC Mode) Conforming to AC input
No load loss(Battery Mode) ≤2.5% rated power
No load loss(AC Mode) ≤2%rated power( charger does not work in AC mode)
No load loss(Energy saving Mode) ≤10W
Phase 3/N/PE
Battery Type VRLA Battery Charge Voltage :13.8V; Float Voltage:13.7V(Single battery voltage)
Customize battery
Charging and discharging parameters of different types of batteries can be customized according to user requirements
(charging and discharging parameters of different types of batteries can be set through the operation panel)
Protection Battery undervoltage alarm 11V(Single battery voltage)
Battery undervoltage protection 10.5V(Single battery voltage)
Battery overvoltage alarm 15V(Single battery voltage)
Battery overvoltage protection 17V(Single battery voltage)
Battery overvoltage recovery voltage 14.5V(Single battery voltage)
Overload power protection Automatic protection (battery mode), circuit breaker or insurance (AC mode)
Inverter output short circuit protection Automatic protection (battery mode), circuit breaker or insurance (AC mode)
Temperature protection >90°C(Shut down output)
Alarm A Normal working condition, buzzer has no alarm sound
B Buzzer sounds 4 times per second when battery failure, voltage abnormality, overload protection
C When the machine is turned on for the first time, the buzzer will prompt 5 when the machine is normal
Inside Solar controller
(Optional)
Charging Mode MPPT or PWM
Charging current
PWM: 10A-60A(48V System); 50A/100A(96V System); 50A/100A(192V System)
MPPT: 10A-100A(48V System); 50A/100A(96V System)
PV Input Voltage Range
PWM: 60V-88V(48V System); 120V-176V(96V System); 240V-352V(192V System)
MPPT: 60V-120V(48V System); 120V-240V(96V System); 240V-360V(192V System)
Max PV Input Voltage(Voc)
(At the lowest temperature)
PWM: 100V(48V System); 200V(96V System); 400V(192V System)
MPPT: 150V(48 System); 300V(96V System); 450V(192V System)
PV Array Maximum Power
48V System: 560W(10A)/1120W(20A)/1680W(30A)/2240W(40A)/2800W(50A)/3360W(60A)/4480W(80A)/5600W(100A);
96V System: (PWM: 5.6KW(50A)/11.2KW(100A)) / (MPPT: 5.6KW(50A)/5.6KW*2(100A));
192V System: (PWM: 11.2KW(50A)/22.4KW(100A))
Standby loss ≤3W
Maximum conversion efficiency >95%
Working Mode Battery First/AC First/Saving Energy Mode
Transfer Time ≤4ms
Display LCD
Thermal method Forced air cooling
Communication(Optional) RS485/APP(WIFI monitoring or GPRS monitoring)
Environment Operating temperature -10℃~40℃
Storage temperature -15℃~60℃
Noise 2000m(More than derating)
Elevation ≤65dB
Humidity 0%~95% ,No condensation
1. Contact us for 15kw 3 phase inverter, 25kw 3 phase inverter technical specification

2. Note: All specifications are subject to charge without prior notice

 

■ 3 Phase Off Grid Hybrid Solar Inverter Details

■ 3 Phase Off Grid Hybrid Solar Inverter Wiring Diagram

We offer 2 optional working modes for 3 phase hybrid solar inverter (transfer time≤4ms):

1. Home or Industry Backup System:
When AC grid power is available, inverter charges battery, at the same time, AC grid power bypass through inverter to household/industrial appliances, such as refrigerator, drill, water pump, etc. When AC grid power is off, it will automatic transfer switch to battery power and convert DC to AC power.

2. Wind or Solar Power system:
Convert DC to AC power. When battery power is lacking, it will automatic transfer to grid power for powering continuously.

 

■ 3 Phase Off Grid Hybrid Solar Inverter Application

■ Inverter Package and Delivery

Rated Power

10KVA/8KW/48VDC, 10KVA/8KW/96VDC, 10KVA/8KW/192VDC, 12.5KVA/10KW/48VDC, 12.5KVA/10KW/96VDC, 12.5KVA/10KW/192VDC, 15KVA/12KW/48VDC, 15KVA/12KW/96VDC, 15KVA/12KW/192VDC, 20KVA/16KW/96VDC, 20KVA/16KW/192VDC, 25KVA/20KW/96VDC, 25KVA/20KW/192VDC, 30KVA/24KW/96VDC, 30KVA/24KW/192VDC