■ Solar Charge Inverter Feature
1. Pure sine wave high frequency solar inverter, high efficiency and low no-load loss;
2. MPPT solar charge controller and inverter combo, It is the most popular integrated design in the market;
3. Battery charge and discharge voltage parameters can be set, Suitable for lead-acid battery, lithium ion battery, gel battery and other battery types;
4. Support solar energy, mains power and generator input, stabilized voltage output;
5. Off grid solar inverter can work without battery optional, saving the cost of solar power system;
6. RS485 communication port/APP optional, convenient to remotely monitor the operation status of the solar charge inverter
■ Solar Charge Inverter Specification
Specification | |||||||||||
Model: HP pro-T | 10212 | 15224 | 20224 | 32224L | 32224 | 50248L | 50248 | 72248 | 80248 | ||
Rated Power | 1000W | 1500W | 2000W | 3200W | 3200W | 5000W | 5000W | 7200W | 8000W | ||
Peak Power(20ms) | 3000VA | 4.5KVA | 6KVA | 9.6KVA | 9.6KVA | 15KVA | 15KVA | 21.6KVA | 24KVA | ||
Battery Voltage | 12VDC | 24VDC | 48VDC | ||||||||
Product Size(L*W*Hmm) | 355x272x91.5 | 400x315x101.5 | 440x342x101.5 | 525x355x115 | |||||||
Package Size(L*W*Hmm) | 443x350x187 | 488x393x198 | 528x420x198 | 615x435x210 | |||||||
N.W(Kg) | 6.5 | 8.5 | 10 | 14 | |||||||
G.W(Kg) | 7.5 | 9.5 | 11 | 15.5 | |||||||
Installation Method | Wall-Mounted | ||||||||||
PV | Charging Mode | MPPT | |||||||||
MPPT tracking voltage range | 15V-80VDC | 30V-100VDC | 120V-450VDC | 60V-140VDC | 120V-450VDC | ||||||
Rated (recommended) operating voltage of PV array | 15V-30VDC | 30V-60VDC | 360VDC | 60V-90VDC | 360VDC | ||||||
Max PV Input Voltage Voc (At the lowest temperature) |
120VDC | 500VDC | 180VDC | 500VDC | |||||||
PV Array Maximum Power | 840W | 1680W | 4000W | 3360W | 6000W | 4500Wx2 | |||||
MPPT tracking channels (input channels) | 1 | 2 | |||||||||
Input | DC Input Voltage Range | 10.5-15VDC | 21VDC-30VDC | 42VDC-60VDC | |||||||
Rated AC input voltage | 220VAC / 230VAC / 240VAC | ||||||||||
AC Input Voltage Range | 170VAC~280VAC (UPS mode)/ 120VAC~280VAC(INV mode) | ||||||||||
AC Input Frequency Range | 45Hz~55Hz(50Hz),55Hz~65Hz(60Hz) | ||||||||||
Output | Output efficiency(Battery/PV Mode) | 94%(Peak value) | |||||||||
Output Voltage(Battery/PV Mode) | 220VAC±2% / 230VAC±2% / 240VAC±2% | ||||||||||
Output Frequency(Battery/PV Mode) | 50Hz±0.5 or 60Hz±0.5 | ||||||||||
Output Wave(Battery/PV Mode) | Pure Sine Wave | ||||||||||
Efficiency(AC Mode) | >99% | ||||||||||
Output Voltage(AC Mode) | Follow input | ||||||||||
Output Frequency(AC Mode) | Follow input | ||||||||||
Output waveform distortion Battery/PV Mode) |
≤3%(Linear load) | ||||||||||
No load loss(Battery Mode) | ≤1% rated power | ||||||||||
No load loss(AC Mode) | ≤0.5% rated power(charger does not work in AC mode) | ||||||||||
Battery | Battery Type |
VRLA Battery | Charge Voltage :13.8V; Float Voltage:13.7V(Single battery voltage) | ||||||||
Customize battery | Charging and discharging parameters of different types of batteries can be customized according to user requirements (charging and discharging parameters of different types of batteries can be set through the operation panel) |
||||||||||
Maximum charging current (mains + PV) | 120A | 100A | 110A | 120A | 100A | 120A | 100A | 150A | |||
Max PV Charging Current | 60A | 60A | 60A | 60A | 100A | 60A | 100A | 150A | |||
Max AC Charging Current | 60A | 40A | 50A | 60A | 60A | 60A | 60A | 80A | |||
Charging method | Three-stage (constant current, constant voltage, floating charge) | ||||||||||
Protection | Battery low voltage alarm | Battery undervoltage protection value+0.5V(Single battery voltage) | |||||||||
Battery low voltage protection | Factory default: 10.5V(Single battery voltage) | ||||||||||
Battery over voltage alarm | Constant charge voltage+0.8V(Single battery voltage) | ||||||||||
Battery over voltage protection | Factory default: 17V(Single battery voltage) | ||||||||||
Battery over voltage recovery voltage | Battery overvoltage protection value-1V(Single battery voltage) | ||||||||||
Overload power protection | Automatic protection (battery mode), circuit breaker or insurance (AC mode) | ||||||||||
Inverter output short circuit protection | Automatic protection (battery mode), circuit breaker or insurance (AC mode) | ||||||||||
Temperature protection | >90°C(Shut down output) | ||||||||||
Working Mode | Mains priority/PV priority/Battery priority(Can be set) | ||||||||||
Transfer Time | ≤10ms | ||||||||||
Display | LCD+LED | ||||||||||
Thermal method | Cooling fan in intelligent control | ||||||||||
Communication(Optional) | RS485/APP(WIFI monitoring or GPRS monitoring) | ||||||||||
Environment | Operating temperature | -10℃~40℃ | |||||||||
Storage temperature | -15℃~60℃ | ||||||||||
Noise | ≤55dB | ||||||||||
Elevation | 2000m(More than derating) | ||||||||||
Humidity | 0%~95% (No condensation) | ||||||||||
Note: 1. Model of 10212/15224/20224/32224L/50248L only support mains priority mode and battery priority mode, PV priority work mode is not supported. 2. All specifications are subject to charge without prior notice. |