LST Off Grid Hybrid Solar Inverter 1KW-3KW 12V/24V/48V Manufacturer

$640.00$940.00

+ Free Shipping

1KW/1.5KW/2KW/3KW, DC12V/24V/48V to AC110V/120V/220V/230V/240V | Inverter with MPPT/PWM Charge Controller | Hybrid Solar Inverter for Off Grid System

  • Type :DC to AC Off-Grid Inverter
  • Brand :BigBear
  • Verification: CE / FC / IEC/ ISO / RoHS

Hybrid Solar Inverter Feature

 


1 Pure sine wave output;
2 Low frequency toroidal transformer lower loss;
3 Intelligent LCD integration display;
4 Hybrid solar inverter with built-in PWM or MPPT controller optional;
5 AC charge current 0~30A adjustable, three working modes selectable;
6 Peak power more than 3 times, full-automatic and perfect protection function;
7 Added fault code query function, easy to monitor the operation in real time;
8 Supports diesel or gasoline generator, adapt any tough electricity situation;
9 Inverter combine industrial and home usage, wall-mounted design, convenient installation.

Off Grid Hybrid Solar Inverter Specification

 


 

 

 

Specification
Model LS-T
10212/24/48
(102)
15212/24/48
(152)
20212/24/48
(202)
30224/48
(302)
Rated Power 1KW 1.5KW 2KW 3KW
Peak Power(20ms) 3KVA 4.5KVA 6KVA 9KVA
Start Motor 1HP 1.5HP 2HP 3HP
Battery Voltage 12/24/48VDC 24/48VDC
Size(L*W*Hmm) 500*300*140
Packing Size(L*W*Hmm) 565*395*225
N.W.(kg) 12 13.5 18 20
G.W.(kg)(Carton Packing) 13.5 15 19.5 21.5
Installation Method Wall-Mounted
Parameter
Input DC Input Voltage Range 10.5-15VDC(Single battery voltage)
AC Input Voltage Range
85VAC~138VAC(110VAC) / 95VAC~148VAC(120VAC) / 170VAC~275VAC(220VAC) /
180VAC~285VAC(230VAC) / 190VAC~295VAC(240VAC)
AC Input Frequency Range 45Hz~55Hz(50Hz) / 55Hz~65Hz(60Hz)
Max AC charging current 0~30A(Depends on model)
AC charging method Three-stage (constant current, constant voltage, floating charge)
Output Efficiency(Battery Mode) ≥85%
Output Voltage(Battery Mode) 110VAC±2% / 120VAC±2% / 220VAC±2% / 230VAC±2% / 240VAC±2%
Output Frequency(Battery Mode) 50/60Hz±1%
Output Wave(Battery Mode) Pure Sine Wave
Efficiency(AC Mode) >99%
Output Voltage(AC Mode) 110VAC±10% / 120VAC±10% / 220VAC±10% / 230VAC±10% / 240VAC±10%
Output Frequency(AC Mode) Tracking Automatically
Output waveform distortion
(Battery Mode)
≤3%(Linear load)
No load loss(Battery Mode) ≤0.8% rated power
No load loss(AC Mode) ≤2% rated power( charger does not work in AC mode)
No load loss
(Energy saving Mode)
≤10W
Battery Type VRLA Battery Charge Voltage :14.2V; Float Voltage:13.8V(Single battery voltage)
Customize battery
Charging and discharging parameters of different types of batteries can be customized according to user requirements
(charging and discharging parameters of different types of batteries can be set through the operation panel)
Protection Battery undervoltage alarm Factory default: 11V(Single battery voltage)
Battery undervoltage protection Factory default: 10.5V(Single battery voltage)
Battery overvoltage alarm Factory default: 15V(Single battery voltage)
Battery overvoltage protection Factory default: 17V(Single battery voltage)
Battery overvoltage recovery voltage Factory default: 14.5V(Single battery voltage)
Overload power protection Automatic protection (battery mode), circuit breaker or insurance (AC mode)
Inverter output short circuit protection Automatic protection (battery mode), circuit breaker or insurance (AC mode)
Temperature protection >90°C(Shut down output)
Alarm A Normal working condition, buzzer has no alarm sound
B Buzzer sounds 4 times per second when battery failure, voltage abnormality, overload protection
C When the machine is turned on for the first time, the buzzer will prompt 5 when the machine is normal
Inside Solar controller
(Optional)
Charging Mode MPPT or PWM
Charging current 10A~60A(PWM or MPPT)
PV Input Voltage Range
PWM: 15V-44V(12V System); 30V-44V(24V System); 60V-88V(48V System)
MPPT: 15V-120V(12V System); 30V-120V(24V System); 60V-120V(48V System)
Max PV Input Voltage(Voc)
(At the lowest temperature)
PWM: 50V(12V/24V System ); 100V(48V System) / MPPT: 150V
PV Array Maximum Power
12V System: 140W(10A)/280W(20A)/420W(30A)/560W(40A)/700W(50A)/840W(60A);
24V System: 280W(10A)/560W(20A)/840W(30A)/1120W(40A)/1400W(50A)/1680W(60A);
48V System: 560W(10A)/1120W(20A)/1680W(30A)/2240W(40A)/2800W(50A)/3360W(60A)
Standby loss ≤3W
Maximum conversion efficiency >95%
Working Mode Battery First/AC First/Saving Energy Mode
Transfer Time ≤4ms
Display LCD
Thermal method Cooling fan in intelligent control
Communication RS485/APP(WIFI monitoring or GPRS monitoring)
Environment Operating temperature ≤55dB
Storage temperature -10℃~40℃
Noise -15℃~60℃
Elevation 2000m(More than derating)
Humidity 0%~95% ,No condensation
Note: All specifications are subject to charge without prior notice

 


 

■ Off Grid Hybrid Solar Inverter Details

 

■ Off Grid Hybrid Solar Inverter Wiring Diagram

 


Hybrid Solar Inverter Application

 


 

BigBear LLC hybrid solar inverter usually has two application methods:

1. Home backup system:

When AC grid power is available, inverter charges battery, at the same time, AC grid power bypass through inverter to home appliances, such as light, refrigerator, television, air-conditioner. When AC grid power is off, inverter will automatic transfer switch to battery power and convert DC to AC power.

2. Wind or Solar Energy system:
The electricity generated by solar or wind energy is DC (direct current), then inverter will convert DC to AC power. When battery power is lacking, it will automatic transfer to grid power for powering continuously.

Inverter Package and Delivery

 

Rated Power

1000W/12V PWM30A, 1500W/12V PWM30A, 2000W/12V PWM30A, 1000W/24V PWM30A, 1500W/24V PWM30A, 2000W/24V PWM30A, 3000W/24V PWM30A, 1500W/48V PWM30A, 2000W/48V PWM30A, 3000W/48V PWM30A

Shopping Cart