■ Off Grid Hybrid Solar Inverter Charger Feature
1 Off grid hybrid solar inverter built-in PWM charge controller.
2 Pure sine wave output.
3 Wide AC voltage input range, AVR output.
4 Adopt low frequency transformer , stable performance.
5 LCD/LED&LCD real-time display, concise and straightforward.
6 Working modes: AC first or battery first optional, intelligent charging.
7 RS232 communication port optional.
0 Factory wholesales off grid dc ac inverter charger, you will get a better price than on the market about intelligent dc ac inverter.
■ Off Grid Hybrid Solar Inverter Charger Specification
Specification | |||||
Model NBT | 70296/192 | 80396/192 | 10396/192 | 12396/192 | |
Rated Power | 7KW | 8KW | 10KW | 12KW | |
Peak Power(20ms) | 21KVA | 24KVA | 30KVA | 36KVA | |
Start Motor | 5HP | 6HP | 7HP | 7HP | |
Battery Voltage | 96/192VDC | 96/192VDC | 96/192VDC | 96/192VDC | |
Size(L*W*Hmm) | 485*300*646 | ||||
Packing Size(L*W*Hmm) | 550*365*785 | ||||
N.W.(kg) | 62 | 64 | 66 | 70 | |
G.W.(kg) | 72 | 74 | 77 | 80 | |
Installation Method | Tower | ||||
Parameter | |||||
Input | DC Input Voltage Range | 10.5-15VDC(Single battery voltage) | |||
AC Input Voltage Range |
73VAC~138VAC(110VAC) / 83VAC~148VAC(120VAC) / 145VAC~275VAC(220VAC) /
155VAC~285VAC(230VAC) / 165VAC~295VAC( 240VAC)
|
92VAC~128VAC(110VAC) / 102VAC~138VAC(120VAC) / 185VAC~255VAC(220VAC) /
195VAC~265VAC(230VAC) / 205VAC~275VAC( 240VAC)
|
|||
AC Input Frequency Range | 45Hz~55Hz(50Hz) / 55Hz~65Hz(60Hz) | ||||
Max AC charging current | 6A~15A(Depending on the model) | ||||
AC charging voltage | LEAD battery:Charge Voltage :14.2V; Float Voltage:13.8V(Single battery voltage) | ||||
AC charging method | Three-stage (constant current, constant voltage, floating charge) | ||||
Output | Efficiency(Battery Mode) | ≥85% | |||
Output Voltage(Battery Mode) | 110VAC±2% / 120VAC±2% / 220VAC±2% / 230VAC±2% / 240VAC±2% | ||||
Output Frequency(Battery Mode) | 50Hz±0.5 or 60Hz±0.5 | ||||
Output Wave(Battery Mode) | Pure Sine Wave | ||||
Efficiency(AC Mode) | >99% | ||||
Output Voltage(AC Mode) | Follow input | ||||
Output Frequency(AC Mode) | Tracking Automatically | ||||
Output waveform distortion
(Battery Mode)
|
≤3%(Linear load) | ||||
No load loss(Battery Mode) | ≤2.5% rated power | ≤1% rated power | |||
No load loss(AC Mode) | ≤2% rated power( charger does not work in AC mode) | ||||
No load loss(Energy saving Mode) | ≤10W | ||||
Battery Type | VRLA Battery | Charge Voltage :14.2V; Float Voltage:13.8V(Single battery voltage) | |||
Customize battery | Charge and discharge parameters of different types of batteries (such as lithium batteries, etc.) can be customized according to user requirements | ||||
Protection | Battery undervoltage alarm | Factory default: 11V(Single battery voltage) | |||
Battery undervoltage protection | Factory default: 10.5V(Single battery voltage) | ||||
Battery overvoltage alarm | Factory default: 15V(Single battery voltage) | ||||
Battery overvoltage protection | Factory default: :17V(Single battery voltage) | ||||
Battery overvoltage recovery voltage | Factory default: 14.5V(Single battery voltage) | ||||
Overload power protection | Automatic protection (battery mode), circuit breaker or insurance (AC mode) | ||||
Inverter output short circuit protection | Automatic protection (battery mode), circuit breaker or insurance (AC mode) | ||||
Temperature protection | >90°C(Shut down output) | ||||
Alarm | A | Normal working condition, buzzer has no alarm sound | |||
B | Buzzer sounds 4 times per second when battery failure, voltage abnormality, overload protection | ||||
C | When the machine is turned on for the first time, the buzzer will prompt 5 when the machine is normal | ||||
Inside Solar controller
(Optional)
|
Charging Mode | PWM | |||
Charging current | 50A/100A | ||||
PV Input Voltage Range | 120V-176V(96V System); 240V-352V(192V System) | ||||
Max PV Input Voltage(Voc)
(At the lowest temperature)
|
200V(96V System); 400V(192V System) | ||||
PV Array Maximum Power | 96V System: 5.6KW(50A)/11.2KW(100A) ; 192V System: 11.2KW(50A)/22.4KW(100A) | ||||
Standby loss | ≤3W | ||||
Maximum conversion efficiency | >95% | ||||
Working Mode | Battery First/AC First/Saving Energy Mode | ||||
Transfer Time | ≤4ms | ||||
Display | LCD | ||||
Thermal method | Cooling fan in intelligent control | ||||
Communication | RS232(Optional) | ||||
Environment | Operating temperature | -10℃~40℃ | |||
Storage temperature | -15℃~60℃ | ||||
Noise | ≤55dB | ||||
Elevation | 2000m(More than derating) | ||||
Humidity | 0%~95% ,No condensation | ||||
Note: All specifications are subject to charge without prior notice |
■ Off Grid Hybrid Solar Inverter Charger Details
7kw solar inverter:
8kw/10kw/12kw hybrid inverter:
■ Off Grid Hybrid Solar Inverter Charger Wiring Diagram
7 kw hybrid solar inverter wiring diagram:
8kw/10kw/12kw hybrid solar inverter wiring diagram:
BigBear LLC off grid solar inverter usually has two application methods:
1. Home Backup System:
When AC grid power is available, inverter charges battery, at the same time, AC grid power bypass and stable voltage through inverter to home appliances, such as lamp, refrigerator, air-conditioner, computer. When AC grid power is off, inverter will automatic transfer switch to battery power and convert DC to AC power.
2. Wind or Solar Power system:
The electricity generated by solar or wind energy is DC (direct current), then inverter will convert DC to AC power. When battery power is lacking, it will automatic transfer to grid power for powering continuously.
■ Off Grid Hybrid Solar Inverter Charger Application
■ Inverter Package and Delivery