■ Household Inverter Feature
■ Household Inverter Specification
Specification | ||||
Model NB | 40248/96 | 50248/96/192 | 60248/96/192 | |
Rated Power | 4KW | 5KW | 6KW | |
Peak Power(20ms) | 12KVA | 15KVA | 18KVA | |
Start Motor | 3HP | 4HP | 4HP | |
Battery Voltage | 48/96VDC | 48/96/192VDC | ||
Size(L*W*Hmm) | 460*245*445 | |||
Packing Size(L*W*Hmm) | 530*310*550 | |||
N.W.(kg) | 46 | 52 | 53 | |
G.W.(kg) | 48(Carton Packing) | 58(Wooden Packing) | 59(Wooden Packing) | |
Installation Method | Tower | |||
Parameter | ||||
Input | DC Input Voltage Range | 10.5-15VDC(Single battery voltage) | ||
AC Input Voltage Range | 73VAC~138VAC(110VAC) / 83VAC~148VAC(120VAC) / 145VAC~275VAC(220VAC) / 155VAC~285VAC(230VAC) / 165VAC~295VAC( 240VAC) |
|||
AC Input Frequency Range | 45Hz~55Hz(50Hz) / 55Hz~65Hz(60Hz) | |||
Max AC charging current | 6A~15A(Depending on the model) | |||
AC charging voltage | LEAD battery:Charge Voltage :14.2V; Float Voltage:13.8V(Single battery voltage) | |||
AC charging method | Three-stage (constant current, constant voltage, floating charge) | |||
Output | Efficiency(Battery Mode) | ≥85% | ||
Output Voltage(Battery Mode) | 110VAC±2% / 120VAC±2% / 220VAC±2% / 230VAC±2% / 240VAC±2% | |||
Output Frequency(Battery Mode) | 50Hz±0.5 or 60Hz±0.5 | |||
Output Wave(Battery Mode) | Pure Sine Wave | |||
Efficiency(AC Mode) | >99% | |||
Output Voltage(AC Mode) | Follow input | |||
Output Frequency(AC Mode) | Tracking Automatically | |||
Output waveform distortion (Battery Mode) |
≤3%(Linear load) | |||
No load loss(Battery Mode) | ≤2.5% rated power | |||
No load loss(AC Mode) | ≤2% rated power( charger does not work in AC mode) | |||
No load loss(Energy saving Mode) | ≤10W | |||
Battery Type | VRLA Battery | Charge Voltage :14.2V; Float Voltage:13.8V(Single battery voltage) | ||
Customize battery | Charge and discharge parameters of different types of batteries (such as lithium batteries, etc.) can be customized according to user requirements | |||
Protection | Battery undervoltage alarm | Factory default: 11V(Single battery voltage) | ||
Battery undervoltage protection | Factory default: 10.5V(Single battery voltage) | |||
Battery overvoltage alarm | Factory default: 15V(Single battery voltage) | |||
Battery overvoltage protection | Factory default: :17V(Single battery voltage) | |||
Battery overvoltage recovery voltage | Factory default: 14.5V(Single battery voltage) | |||
Overload power protection | Automatic protection (battery mode), circuit breaker or insurance (AC mode) | |||
Inverter output short circuit protection | Automatic protection (battery mode), circuit breaker or insurance (AC mode) | |||
Temperature protection | >90°C(Shut down output) | |||
Alarm | A | Normal working condition, buzzer has no alarm sound | ||
B | Buzzer sounds 4 times per second when battery failure, voltage abnormality, overload protection | |||
C | When the machine is turned on for the first time, the buzzer will prompt 5 when the machine is normal | |||
Working Mode | Battery First/AC First/Saving Energy Mode | |||
Transfer Time | ≤4ms | |||
Display | LCD | |||
Thermal method | Cooling fan in intelligent control | |||
Communication | RS232(Optional) | |||
Environment | Operating temperature | -10℃~40℃ | ||
Storage temperature | -15℃~60℃ | |||
Noise | ≤55dB | |||
Elevation | 2000m(More than derating) | |||
Humidity | 0%~95% ,No condensation | |||
Note: All specifications are subject to charge without prior notice |
■ Household Inverter Details
■ Household Inverter Wiring Diagram
BigBear LLC inverter usually has the following two method of application:
1. House Backup System:
When AC grid power is available, inverter charges battery, at the same time, AC grid power bypass through inverter to house appliances, such as rice cooker, refrigerator, aic-conditinoer, etc. When AC grid power is cut off, inverter will automatic transfer switch to battery power and convert DC to AC power.
2. Wind or Solar Power System:
The electricity generated by solar or wind energy is DC (direct current), inverter will convert DC to AC power. When battery power is lacking, it will automatic transfer to AC grid power for powering continuously.
■ Household Inverter Application
■ Inverter Package and Delivery