NBT Inversor Solar Hibrido 30KW/40KW 240V/384V

$10,140.00$14,285.00

+ Free Shipping

30KW/40KW DC240V/384V a AC110V/120V/220V/230V/240V | Inversor Hibrido Con Cargador Incorporado PWM 50A/100A/150A/200A | potencia inversores solares fotovoltaicos

  • Type :DC to AC Off-Grid Inversor
  • Brand : BigBear
    Verification: CE / FC / IEC/ ISO / RoHS 

■ Inversor Solar Hibrido Feature

 


 

1 Inversor hibrido built-in PWM charge controller optional.
2 Pure sine wave output.
3 Wide AC voltage input range, AVR output.
4 Adopt traditional EI transformer , stable performance.
5 LCD/LED&LCD real-time display, concise and straightforward.
6 Working modes: AC first or battery first optional, intelligent charging.
7 RS232 communication port optional.
■ Inversor Solar Hibrido Specification

 


 

 

Specification
Model NB-T 303240 403384
Rated Power 30KW 40KW
Peak Power(20ms) 90KVA 120KVA
Start Motor 15HP 30HP
Battery Voltage 240VDC 384VDC
Size(L*W*Hmm) 720*435*1120
Packing Size(L*W*Hmm) 790*505*1260
N.W.(kg) 135 160
G.W.(kg) 150 180
Installation Method Tower
Parameter
Input DC Input Voltage Range 10.5-15VDC(Single battery voltage)
AC Input Voltage Range
92VAC~128VAC(110VAC) / 102VAC~138VAC(120VAC) / 185VAC~255VAC(220VAC) /
195VAC~265VAC(230VAC) / 205VAC~275VAC( 240VAC)
AC Input Frequency Range 45Hz~55Hz(50Hz) / 55Hz~65Hz(60Hz)
Max AC charging current 6A~15A(Depending on the model)
AC charging voltage LEAD battery:Charge Voltage :14.2V; Float Voltage:13.8V(Single battery voltage)
AC charging method Three-stage (constant current, constant voltage, floating charge)
Output Efficiency(Battery Mode) ≥85%
Output Voltage(Battery Mode) 110VAC±2% / 120VAC±2% / 220VAC±2% / 230VAC±2% / 240VAC±2%
Output Frequency(Battery Mode) 50Hz±0.5 or 60Hz±0.5
Output Wave(Battery Mode) Pure Sine Wave
Efficiency(AC Mode) >99%
Output Voltage(AC Mode) Follow input
Output Frequency(AC Mode) Tracking Automatically
Output waveform distortion
(Battery Mode)
≤3%(Linear load)
No load loss(Battery Mode) ≤1% rated power
No load loss(AC Mode) ≤2% rated power( charger does not work in AC mode)
No load loss(Energy saving Mode) ≤10W
Battery Type VRLA Battery Charge Voltage :14.2V; Float Voltage:13.8V(Single battery voltage)
Customize battery Charge and discharge parameters of different types of batteries (such as lithium batteries, etc.) can be customized according to user requirements
Protection Battery undervoltage alarm Factory default: 11V(Single battery voltage)
Battery undervoltage protection Factory default: 10.5V(Single battery voltage)
Battery overvoltage alarm Factory default: 15V(Single battery voltage)
Battery overvoltage protection Factory default: :17V(Single battery voltage)
Battery overvoltage recovery voltage Factory default: 14.5V(Single battery voltage)
Overload power protection Automatic protection (battery mode), circuit breaker or insurance (AC mode)
Inverter output short circuit protection Automatic protection (battery mode), circuit breaker or insurance (AC mode)
Temperature protection >90°C(Shut down output)
Alarm A Normal working condition, buzzer has no alarm sound
B Buzzer sounds 4 times per second when battery failure, voltage abnormality, overload protection
C When the machine is turned on for the first time, the buzzer will prompt 5 when the machine is normal
Inside Solar controller
(Optional)
Charging Mode PWM
Charging current 50A/100A/150A/200A(PWM)
PV Input Voltage Range 300V-440V(240V System); 480V-704V(384V System)
Max PV Input Voltage(Voc)
(At the lowest temperature)
500V(240V System); 750V(384V System)
PV Array Maximum Power
240V System: 14KW(50A)/28KW(100A)/21KW*2(150A)/28KW*2(200A);
384V System: 22.4KW(50A)/44.8KW(100A)/33.6KW*2(150A)/44.8KW*2(200A)
Standby loss ≤3W
Maximum conversion efficiency >95%
Working Mode Battery First/AC First/Saving Energy Mode
Transfer Time ≤4ms
Display LCD
Thermal method Cooling fan in intelligent control
Communication RS232(Optional)
Environment Operating temperature -10℃~40℃
Storage temperature -15℃~60℃
Noise ≤55dB
Elevation 2000m(More than derating)
Humidity 0%~95% ,No condensation
Note: All specifications are subject to charge without prior notice

 

 

■ Inversor Solar Hibrido Details

■ Inversor Solar Hibrido Wiring Diagram

BigBear LLC inversor solar hibrido usually has two application methods:

1. Home Backup System:
When AC grid power is available, inverter charges battery, at the same time, AC grid power bypass and stable voltage through inverter to home appliances, such as induction cooker, kettle, refrigerator, air-conditioner. When AC grid power is off, inverter will automatic transfer switch to battery power and convert DC to AC power.

2. Wind or Solar Power system:
The electricity generated by solar or wind energy is DC (direct current), then inverter will convert DC to AC power. When battery power is lacking, it will automatic transfer to grid power for powering continuously.

 

■ Inversor Solar Hibrido Application

■ Inversor Package and Delivery

Rated Power

30KW/240V(PWM50A), 40KW/384V(PWM50A)

Shopping Cart