■ PWM Solar PV Charge Controller Feature
1 LCD display PV charge, battery and DC loading condition.
2 Protection against over charge, over discharge, over load and anti-thunder.
3 PWM charging mode, DC mode save cost.
■ PWM Solar PV Charge Controller Specification
KY1 Parameter | ||
Rated charging current | 150A | 200A |
Rated system voltage | 96V/192V/216V/240V/384V | |
PV input voltage range | 96V System:120V-176V;192V System:240V-352V;216V System:270V-396V;240V System:300V-440V;384V System:480V-704V | |
Max PV Input Voltage (At the lowest temperature) |
96V System:200V;192V System:400V;216V System:450V;240V System:500V;384V System:750V | |
Number of PV array input routes | 2 | |
PV Array Maximum Power | 8.4KW*2/16.8KW*2/18.9KW*2/21KW*2/33.6KW*2 | 11.2KW*2/22.4KW*2/25.2KW*2/28KW*2/44.8 KW *2 |
Battery type | Lead acid battery, deep cycle battery, gel battery etc(Battery type base on user charge specification) | |
Floating voltage | 13.8V/Single battery | |
Charge voltage | 14.2V/Single battery | |
Charging protection voltage | 15V/Single battery | |
Temperature compensation coefficient | -3mV / ℃ / 2V (25℃ is base line )(Optional) | |
Charging mode | PWM pulse width control | |
Charging method | Three stages :constant current; constant voltage; floating charge | |
Efficiency | >95% | |
Display | LCD | |
Cooling method | Cooling fan in intelligent control | |
Type of mechanical protection | IP20 | |
Operating temperature | -20℃~+60℃ | |
Storage temperature | -20℃~+70℃ | |
Elevation | <5000m,(Less solar panel when exceed 2000m) | |
Humidity | 5~95%(No condense) | |
Protect the circuit | RS232/RS485(Optional) | |
Machine size (L*W*Hmm) | 500*330*805 | |
Package size (L*W*Hmm) | 565*395*870 | |
N.W (Kg) | 32 | 33 |
G.W (Kg) | 37 | 38 |
Note: All specifications are subject to change without prior notice |
■ PWM Solar PV Charge Controller Image
■ How Does PWM Solar PV Charge Controller Work?