UPS Power Backup 40KVA-80KVA 192V/384VDC

+ Free Shipping

40KVA/50KVA/60KVA/80KVA UPS 192V/384VDC to 380VAC. Multiple Applications: UPS Power Backup for Computer, PC, Home, Office, etc.

  • Type :UPS Power Supply Backup
  • Brand : BigBear
    Verification: CE / FC / IEC/ ISO / RoHS

     

Category: Tags: ,

■ UPS Power Backup Feature


 

1. Three-phase interactive ups power backup, support three-phase unbalanced load, can output single-phase 220V or three-phase 380V.
2. High Performance DSP based full digital controlled, low frequency pure sine wave output.
3. AC charge current 0-45A adjustable.
4. Compatible with diesel or gasoline generators.
5. Good loading adaptability, work well with laser printer, Ultrasonic cleaner.
6. Accept deep customer-oriented, perfect match customer application requirement.

 

 

■ UPS Power Backup Specification


 

Specification
Model: HDSX 40KVA 50KVA 60KVA 80KVA
Rated Power 32KW 40KW 48KW 64KW
Peak Power(20ms) 96KVA 120KVA 144KVA 192KVA
Start Motor 15HP 20HP 25HP 30HP
Battery Voltage 192VDC 384VDC
Size(L*W*Hmm) 720*575*1275
Packing Size(L*W*Hmm) 785*640*1400
N.W.(kg) 287 307 337 355
G.W.(kg)(Wooden Packing) 320 340 370 388
Installation Method Tower
Parameter
Input DC Input Voltage Range 10.5VDC-15VDC(Single battery voltage)
AC Input Voltage Range 380Vac/400Vac±10%(customized 190Vac/200Vac)
AC Input Frequency Range 45Hz-55Hz(50Hz)/ 55Hz-65Hz(60Hz)
Max AC charging current 0-45A(Depending on the model)
AC charging method Three-stage (constant current, constant voltage, floating charge)
Phase 3/N/PE
Output Efficiency(Battery Mode) ≥85%
Output Voltage(Battery Mode) 380Vac/400Vac±10%(customized 190Vac/200Vac)
Output Frequency(Battery Mode) 50/60Hz ±1%
Output Wave(Battery Mode) Pure Sine Wave
Output waveform distortion Linear load≤3%
Efficiency(AC Mode) >99%
Output Voltage(AC Mode) Conforming to AC input
Output Frequency(AC Mode) Conforming to AC input
No load loss(Battery Mode) ≤1% rated power
No load loss(AC Mode) ≤2%rated power( charger does not work in AC mode)
No load loss(Energy saving Mode) ≤10W
Phase 3/N/PE
Battery Type VRLA Battery Charge Voltage :13.8V; Float Voltage:13.7V(Single battery voltage)
Customize battery
Charging and discharging parameters of different types of batteries can be customized according to user requirements
(charging and discharging parameters of different types of batteries can be set through the operation panel)
Protection Battery undervoltage alarm 11V(Single battery voltage)
Battery undervoltage protection 10.5V(Single battery voltage)
Battery overvoltage alarm 15V(Single battery voltage)
Battery overvoltage protection 17V(Single battery voltage)
Battery overvoltage recovery voltage 14.5V(Single battery voltage)
Overload power protection Automatic protection (battery mode), circuit breaker or insurance (AC mode)
Inverter output short circuit protection Automatic protection (battery mode), circuit breaker or insurance (AC mode)
Temperature protection >90°C(Shut down output)
Alarm A Normal working condition, buzzer has no alarm sound
B Buzzer sounds 4 times per second when battery failure, voltage abnormality, overload protection
C When the machine is turned on for the first time, the buzzer will prompt 5 when the machine is normal
Transfer Time ≤4ms
Display LCD
Thermal method Forced air cooling
Communication(Optional) RS485/APP(WIFI monitoring or GPRS monitoring)
Environment Operating temperature -10℃~40℃
Storage temperature -15℃~60℃
Noise 2000m(More than derating)
Elevation ≤65dB
Humidity 0%~95% ,No condensation
Note: All specifications are subject to charge without prior notice

 

 

■ UPS Power Backup Details

■ How Does UPS Power Backup Work?


 

UPS Power backup for home or office:
When AC grid power is available, ups charges battery, at the same time, AC grid power bypass through ups to home appliances, such as computer, refrigerator or water pump. When AC grid power is off, it will automatic transfer switch to battery power and convert DC to AC power.

 

■ UPS Power Backup Package and Shipping

Shopping Cart