■ UPS Power Supply Feature
1 Low frequency pure sine wave ups, Good loading capacity.
2 AC charge current 0-45A adjustable.
3 Wide input voltage range, work well with different power quality.
4 Best ups power supply, 100% imbalance loading design.
5 Setting different working modes based on variable usage requirements, Having ECO mode. Enable best balance between energy saving and power protection.
6 Various communication ports and remote controls (RS232/RS485/APP/SNMP/GSM optional).
■ UPS Power Supply Specification
Specification | |||||||
Model: HDSX | 10KVA | 12.5KVA | 15KVA | 20KVA | 25KVA | 30KVA | |
Rated Power | 8KW | 10KW | 12KW | 16KW | 20KW | 24KW | |
Peak Power(20ms) | 24KVA | 30KVA | 36KVA | 48KVA | 60KVA | 72KVA | |
Start Motor | 5HP | 6HP | 7HP | 10HP | 10HP | 15HP | |
Battery Voltage | 48/96/192VDC | 96/192VDC | |||||
Size(L*W*Hmm) | 725*365*1010 | ||||||
Packing Size(L*W*Hmm) | 785*425*1135 | ||||||
N.W.(kg) | 112 | 122 | 134 | 160 | 176 | 189 | |
G.W.(kg)(Wooden Packing) | 136 | 146 | 158 | 184 | 200 | 213 | |
Installation Method | Tower | ||||||
Parameter | |||||||
Input | DC Input Voltage Range | 10.5VDC-15VDC(Single battery voltage) | |||||
AC Input Voltage Range | 380Vac/400Vac±10%(customized 190Vac/200Vac) | ||||||
AC Input Frequency Range | 45Hz-55Hz(50Hz)/ 55Hz-65Hz(60Hz) | ||||||
Max AC charging current | 0-45A(Depending on the model) | ||||||
AC charging method | Three-stage (constant current, constant voltage, floating charge) | ||||||
Phase | 3/N/PE | ||||||
Output | Efficiency(Battery Mode) | ≥85% | |||||
Output Voltage(Battery Mode) | 380Vac/400Vac±10%(customized 190Vac/200Vac) | ||||||
Output Frequency(Battery Mode) | 50/60Hz ±1% | ||||||
Output Wave(Battery Mode) | Pure Sine Wave | ||||||
Output waveform distortion | Linear load≤3% | ||||||
Efficiency(AC Mode) | >99% | ||||||
Output Voltage(AC Mode) | Conforming to AC input | ||||||
Output Frequency(AC Mode) | Conforming to AC input | ||||||
No load loss(Battery Mode) | ≤2.5% rated power | ||||||
No load loss(AC Mode) | ≤2%rated power( charger does not work in AC mode) | ||||||
No load loss(Energy saving Mode) | ≤10W | ||||||
Phase | 3/N/PE | ||||||
Battery Type | VRLA Battery | Charge Voltage :13.8V; Float Voltage:13.7V(Single battery voltage) | |||||
Customize battery |
Charging and discharging parameters of different types of batteries can be customized according to user requirements
(charging and discharging parameters of different types of batteries can be set through the operation panel)
|
||||||
Protection | Battery undervoltage alarm | 11V(Single battery voltage) | |||||
Battery undervoltage protection | 10.5V(Single battery voltage) | ||||||
Battery overvoltage alarm | 15V(Single battery voltage) | ||||||
Battery overvoltage protection | 17V(Single battery voltage) | ||||||
Battery overvoltage recovery voltage | 14.5V(Single battery voltage) | ||||||
Overload power protection | Automatic protection (battery mode), circuit breaker or insurance (AC mode) | ||||||
Inverter output short circuit protection | Automatic protection (battery mode), circuit breaker or insurance (AC mode) | ||||||
Temperature protection | >90°C(Shut down output) | ||||||
Alarm | A | Normal working condition, buzzer has no alarm sound | |||||
B | Buzzer sounds 4 times per second when battery failure, voltage abnormality, overload protection | ||||||
C | When the machine is turned on for the first time, the buzzer will prompt 5 when the machine is normal | ||||||
Transfer Time | ≤4ms | ||||||
Display | LCD | ||||||
Thermal method | Forced air cooling | ||||||
Communication(Optional) | RS485/APP(WIFI monitoring or GPRS monitoring) | ||||||
Environment | Operating temperature | -10℃~40℃ | |||||
Storage temperature | -15℃~60℃ | ||||||
Noise | 2000m(More than derating) | ||||||
Elevation | ≤65dB | ||||||
Humidity | 0%~95% ,No condensation | ||||||
Note: All specifications are subject to charge without prior notice |
■ UPS Power Supply Details
■ How Does UPS Power Supply Work?
Best UPS power supply can ensure that the computer system will continue to work for a period of time after the power failure, so that users can save files in an emergency, so that you will not be affected by the power failure or lose data. It mainly plays two roles in computer systems and network applications: first, emergency use to prevent sudden power failure from affecting normal work and causing damage to computers; The second is to eliminate the “power pollution” such as power surges, instantaneous high voltage, instantaneous low voltage, wire noise and frequency offset, improve the quality of power supply and provide high-quality power supply for computer systems.
■ UPS Power Supply Package and Shipping