■ UPS Uninterruptible Power Supply Feature
1 Three phase ups design.
2 Pure sine wave output.
3 AC charge current 0-45A adjustable.
4 100% imbalance loading design, suitable for single phase load and three phase load.
5 Backup ups uninterruptible power supply, switching time ≤ 4ms
6 Various communication ports and remote controls (RS232/RS485/APP/SNMP/GSM optional).
■ UPS Uninterruptible Power Supply Specification
Specification | ||||||
Model: HDSX | 100KVA | 120KVA | 125KVA | 150KVA | 160KVA | |
Rated Power | 80KW | 96KW | 100KW | 120KW | 128KW | |
Peak Power(20ms) | 240KVA | 288KVA | 300KVA | 360KVA | 384KVA | |
Start Motor | 40HP | 50HP | 50HP | 60HP | 60HP | |
Battery Voltage | 384VDC | |||||
Size(L*W*Hmm) | 875*720*1380 | |||||
Packing Size(L*W*Hmm) | 980*825*1560 | |||||
N.W.(kg) | 512 | 592 | 612 | 612 | 642 | |
G.W.(kg)(Wooden Packing) | 552 | 632 | 652 | 652 | 692 | |
Installation Method | Tower | |||||
Parameter | ||||||
Input | DC Input Voltage Range | 10.5VDC-15VDC(Single battery voltage) | ||||
AC Input Voltage Range | 380Vac/400Vac±10%(customized 190Vac/200Vac) | |||||
AC Input Frequency Range | 45Hz-55Hz(50Hz)/ 55Hz-65Hz(60Hz) | |||||
Max AC charging current | 0-45A(Depending on the model) | |||||
AC charging method | Three-stage (constant current, constant voltage, floating charge) | |||||
Phase | 3/N/PE | |||||
Output | Efficiency(Battery Mode) | ≥85% | ||||
Output Voltage(Battery Mode) | 380Vac/400Vac±10%(customized 190Vac/200Vac) | |||||
Output Frequency(Battery Mode) | 50/60Hz ±1% | |||||
Output Wave(Battery Mode) | Pure Sine Wave | |||||
Output waveform distortion | Linear load≤3% | |||||
Efficiency(AC Mode) | >99% | |||||
Output Voltage(AC Mode) | Conforming to AC input | |||||
Output Frequency(AC Mode) | Conforming to AC input | |||||
No load loss(Battery Mode) | ≤1% rated power | |||||
No load loss(AC Mode) | ≤2%rated power( charger does not work in AC mode) | |||||
No load loss(Energy saving Mode) | ≤10W | |||||
Phase | 3/N/PE | |||||
Battery Type | VRLA Battery | Charge Voltage :13.8V; Float Voltage:13.7V(Single battery voltage) | ||||
Customize battery |
Charging and discharging parameters of different types of batteries can be customized according to user requirements
(charging and discharging parameters of different types of batteries can be set through the operation panel)
|
|||||
Protection | Battery undervoltage alarm | 11V(Single battery voltage) | ||||
Battery undervoltage protection | 10.5V(Single battery voltage) | |||||
Battery overvoltage alarm | 15V(Single battery voltage) | |||||
Battery overvoltage protection | 17V(Single battery voltage) | |||||
Battery overvoltage recovery voltage | 14.5V(Single battery voltage) | |||||
Overload power protection | Automatic protection (battery mode), circuit breaker or insurance (AC mode) | |||||
Inverter output short circuit protection | Automatic protection (battery mode), circuit breaker or insurance (AC mode) | |||||
Temperature protection | >90°C(Shut down output) | |||||
Alarm | A | Normal working condition, buzzer has no alarm sound | ||||
B | Buzzer sounds 4 times per second when battery failure, voltage abnormality, overload protection | |||||
C | When the machine is turned on for the first time, the buzzer will prompt 5 when the machine is normal | |||||
Transfer Time | ≤4ms | |||||
Display | LCD | |||||
Thermal method | Forced air cooling | |||||
Communication(Optional) | RS485/APP(WIFI monitoring or GPRS monitoring) | |||||
Environment | Operating temperature | -10℃~40℃ | ||||
Storage temperature | -15℃~60℃ | |||||
Noise | 2000m(More than derating) | |||||
Elevation | ≤65dB | |||||
Humidity | 0%~95% ,No condensation | |||||
Note: All specifications are subject to charge without prior notice |
■ UPS Uninterruptible Power Supply Details
■ How Does UPS Uninterruptible Power Supply Work?
UPS uninterruptible power supply is a “backup” UPS. The utility directly supplies power to electric equipment and also charges batteries. Once the quality of the utility power supply is unstable or the power is cut off, the circuit of the utility power will be automatically cut off, and the DC power of the battery will be converted into AC power to take over the task of power supply until the utility power returns to normal. “UPS uninterruptible power supply will not intervene in power supply until the utility power is cut off.” In addition, the alternating current converted from the direct current through the ups uninterruptible power supply is a pure sine wave, which can carry inductive loads, such as electrical appliances with motors.